JSY-MK-194T single-phase two-way electric energy metering module highly integrates measurement and digital communication technology, which can measure, collect and transmit single-phase AC power parameters. It can accurately measure two-way single-phase AC voltage, current, power, power factor, frequency, electricity and other electrical parameters. With 1 TTL level interface, completely isolated circuit, small size, simple interface, easy to be embedded in various equipments that need to measure power consumption, highly cost-effective.
JSY-MK-194T can be widely used in energy-saving transformation, EV charging station, power, communication, railway, transportation, environmental protection, petrochemical, steel and other industries to monitor the current and power consumption of AC equipment.
Features:
1. Collect single-phase two-way AC electrical parameters such as voltage, current, power, factor, frequency and electricity etc.
2. Using dedicated measuring chips and effective value measurement methods, with high measurement accuracy.
3. With 1 TTL communication interface, compatible with 5V/3.3V interface.
4. With Modbus-RTU protocol, which has good compatibility and is convenient for programming.
5. High isolation voltage, withstand voltage up to DC3000V.
Specifications:
Product Model |
JSY-MK-194T |
|
Single-phase AC Input |
Voltage Measuring Range |
1~400V (customizable) |
Current Measuring Range |
10mA~80A (customizable) |
|
Signal Processing |
Using dedicated measuring chip with 24 bit AD sampling. |
|
Overload Capacity |
Current 1.2 times measuring range is sustainable. Voltage 1.5 times, measuring range will not be damaged. |
|
Input Impedance |
Voltage channel>1KΩ/V |
|
Communication Interface |
Interface Type |
1 TTL interface (compatible with 5V/3.3V) |
Communication Protocol |
MODBUS-RTU protocol |
|
Data Format |
Can be set by software, "n, 8,1", "e, 8,1", "o, 8,1", "n, 8,2" |
|
Communication Rate |
The Baud can be set to 9600 and 19200bps, the default Baud 4800bps. |
|
Communication Data |
Multiple electrical parameters such as voltage, current, power, energy and power factor etc., as shown in the Mdobus data log list. |
|
Measurement Accuracy |
Voltage, current, power, electric quantity: < ± 1.0% |
|
Power Supply |
DC single power supply 3.3~5V, power consumption 10mA. |
|
Isolation |
Isolation between the tested power supply and power supply. Isolation withstand voltage 3000VDC. |
|
Working Environment |
Working Temperature |
-40~80 ℃ |
Relative Humidity |
5-95%, no condensation (at 40 ℃) |
|
Altitude |
0-3000 meters |
|
Environment |
No explosions, corrosive gases or conductive dust, no significant shaking, vibration or impact. |
|
Temperature Drift |
≤ 100ppm/℃ |
|
Installation Method |
PCB welding |
|
Module Size |
L60.48xW36.81xH28mm |